Corrosion Protection section
m Stub sorting: {{Oregon-bridge-struct-stub}} using AWB
Line 31:
 
==Corrosion Protection==
The Cape Creek Bridge has been impressed-current [[Cathodic protection | cathodically protected]] (ICCP) from [[corrosion]] since 1991. [[Rebar]] in concrete is highly susceptible to corrosion by [[chloride]] ions from [[seawater]] and [[De-ice | de-icing salts]]. Contractors to the [[Oregon Department of Transportation]] have [[Thermal spraying | plasma-sprayed]] 9500 m<sup>2</sup> of 0.5-mm thick [[zinc ]] onto the exposed concrete to provide a [[Galvanic anode | sacrificial anode]] that corrodes in lieu of the steel rebar.<ref>“Cape Creek Bridge Cathodic Protection Operating Data: 1992-94,” Oregon Dept. of Transportation Report, 1995.</ref> <ref>R. Brousseau, M. Arnott & B. Baldock, “Laboratory Performance of Zinc Anodes for Impressed Current Cathodic Protection of Reinforced Concrete’” ''Corrosion'' '''51''', 8 (Aug 1995): p 639-644.</ref> <ref> B.S. Covino, Jr., S.J. Bullard, G.R. Holcomb, S.D. Cramer, G.E. McGill, and C.B. Cryer, “Bond Strength of Electrochemically Aged Arc-Sprayed Zinc Coatings on Concrete,” ''Corrosion'' '''53''', 5 (May 1997): p 399-411.</ref> <ref>G.R. Holcomb, B.S. Covino, Jr., J.H. Russell, S.J. Bullard, S.D. Cramer, W.K. Collins, J.E. Bennett and H.M. Laylor, “Humectant Use in the Cathodic Protection of Reinforced Concrete,” ''Corrosion'' '''56''', 11 (Nov 2000): p 1140-1157.</ref>
 
==See also==
Line 59:
[[Category:1932 establishments in Oregon]]
 
 
{{USOregon-bridge-struct-stub}}